The PRO-2200 Intelligent Control Module (PRO22IC) is and advanced access control panel capable of providing power and flexibility with its 32-bit CPU architecture, optional TCP/IP protocol support, flash memory for firmware and large local card holder database.
The PRO22IC is designed to operate off-line, making access control decisions independently from a PC or other controlling device. It can also be connected to a host computer for system configuration, alarm monitoring and direct control. Connectivity to the host computer is accomplished via direct serial communications (RS-232 or RS-485) dial-up modem or TCP/IP network connection.
The PRO22IC supports any combination of up to 8 I/O or reader boards to monitor alarm input points, relay output points and access control reader interface points. By offering a modular design, the system can be tailored to meet a wide range of applications, while optimizing cost and mounting space.
The standard PRO22IC accommodates a card database of 20,000 cards, and a standard transaction buffer of 5,000 transactions. The memory expansion module (PRO22M4) allows for a card database of 50,000 cards and a transaction buffer capable of storing 35,000 transactions.
The PRO22IC
is designed with various mounting options available. Units can be mounted in a
rack configuration (PRO22ENC1, PRO22ENC2 and PRO22ENC5) when space is limited,
or in a tile-mount configuration (PRO22ENC3).
Benefits
- True 32-bit microprocessor provides fast transaction processing for the
most demanding network applications.
- Modular hardware architecture provides flexibility and expansion
capabilities.
- Flash memory allows new versions of firmware to be downloaded from the
host computer to the controller(s) through the central network.
- Large, local controller database allows access control decisions to be
made by controller in real time without the need to communicate to the server.
- Seamless optional support for TCP/IP protocols to allow intelligent
controller(s) to tap into a LAN or WAN connectivity.
Features
- Up to 12 intervals per time zone where each interval is a start time, stop
time and day map. The day map indicates the day of the week or holiday.
- Activation and deactivation dates by card.
- Operating modes include locked, unlocked, facility code, card only, card
and PIN, card or PIN and PIN only.
- Up to eight card formats per reader.
- Anti-passback support-free pass and exempt flags, last area accessed, last
reader accessed and time/date of last access.
- Pulse control:single pulse (up to 24 hours) or repeating pulses (on/off in
0.1 second increments, up to 255 times).
|